Chapter 12 Data Communication
Receiving Data From an SF/CSF/NX Series Unit
This section describes how to set up and receive data from an SF/CSF/NX Series
Unit. Note that you cannot send data from a PV Unit to an SF/CSF/NX Series
Unit. In this configuration, you must set a number of communication parameters
for correct operation.
You must purchase a separately available SB-305 serial cable, and SB-90
connector/cable set to connect an SF/CSF/NX Series Unit to your PV Unit.
To connect an SF/CSF/NX Series Unit to your PV Unit
1. Make sure that the power of both units is turned off.
2. Connect the optional SB-305 serial cable to your PV-S1600.
3. Open the cover of the data communications jack of the SF/CSF/NX
Series Unit, and connect the optional SB-90 3-9 pin cable.
4. Use the optional SB-90 9-9 pin connector to connect the two cables.
SB-90 3-9 pin cable
SB-90 9-9 pin connector
PV Unit
SF/CSF/NX Series Unit
SB-305 serial cable