Item Measuring Instrument
Vop voltage setting Voltmeter
3) Equipment connection/Procedure
Vop voltage setting
Input
Connection
Input
Point
Input
Signal
Adjust
Output
Connection
Output
Point
Adjust for
VR1 Voltmeter TP1
Adjust for 4.1 ~ 4.0 V reading
on voltmeter under the
temparature 20 ~ 25 °C.
Make fine adjustment ac-
cording to the following in-
struction.
Watching the LCD at a 36.6° angle to the horizontal, adjust Vop
voltage so that unenergized segments are seen dimly.
ADJUSTMENT
MAIN PCB
1) Items to be adjusted:
2) Adjustment and Test Point Locations
(TOP VIEW)
(BOTTOM VIEW)
TP1
VR1
36.6°
LCD
Eye
Output
Set Voltmeter