Casio EG-800U - Cassiopeia - Win CE 3.0 150 MHz Especificaciones Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 89
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
— 3 —
Current consumption:
NOTES:
1. When measuring these current, it is recommended to use the analog ammeter to make the
measurement easier due to protecting the ammeter from noises.
2. Make LCD display contrast suitable (default) condition before measurement.
3. Measure under the ambient temperature 15˚C~35˚C
*Tapping 5 POWER CONTROL in the OPERATION CHECK Main Menu screen display, the following
display will appear.
Currently CPU clock is 150 MHz
VTClock is 50 MHz
Push Action key to exit
Voltage Detectors:
Main (Rechargeable) Battery:
VDET1B : approximately 3.5 V (Low battery message)
VDET2 : approximately 3.2 V (Forced power OFF)
Back-up Battery:
VDETS : approximately 2.7 V (Low battery message)
Unit Alignment Condition for Data transfer using IrDA :
Operation Mode Input Voltage Current consumption
Main menu of OPERATION Rechargeable Battery : 180mA
CHECK in this manual 4.0 ± 0.1V
* POWER CONTROL of Rechargeable Battery : 370mA
OPERATION CHECK 4.0 ± 0.1V
* POWER CONTROL of AC Adapter : 5.9V ± 0.1V 370mA
OPERATION CHECK
Power/OFF Rechargeable Battery : 1.3mA
4.0 ± 0.1V
Power/OFF Lithium battery for Back-up 1.0mA
3.0 ± 0.1V
Length (L) Angle (A)
L 20 cm A 15˚
A
L
EM-505FEM-505F
Vista de pagina 5