Casio EA-200 Technical Reference Manual de usuario

Busca en linea o descarga Manual de usuario para Calculadoras, organizadores Casio EA-200 Technical Reference. Casio EA-200 Technical Reference User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
–1–
Technical Reference
EA-200
http://world.casio.com/edu/
E
Contents
Sampling ................................................................................................ 2
Analog Sampling .................................................................................... 3
Memory .................................................................................................. 3
Pulse Sampling ...................................................................................... 4
Command Tables ................................................................................... 5
Command 1: Channel Settings .............................................................. 9
Command 3: Sampling and Trigger Settings ........................................ 12
Command 4: Conversion Equation Settings ........................................ 14
Command 5: Data Range Settings ...................................................... 15
Command 7: Status Check .................................................................. 16
Command 10: Power Supply Setting ................................................... 17
RS-232C Communication .................................................................... 17
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - Technical Reference

–1–Technical ReferenceEA-200http://world.casio.com/edu/E ContentsSampling ...

Pagina 2 - Sampling

– 10 –Output ExampleWhen the list is: 85(1010101), 34( 100010), 187(10111011), 204(11001100)<Output Trigger>Following receipt of Command 3, outp

Pagina 3 - Analog Sampling

– 11 –<<FFT>>Frequency characteristics are calculated from sampled values and samplingperiod.The number of FFT target data items (2^n) is

Pagina 4 - Pulse Sampling

– 12 –Command 3:Sampling and Trigger Settings{ 3, Sampling Interval, Number of Samples, Record Time, Trigger Source, TriggerThreshold, Trigger Edge, C

Pagina 5 - Command Tables

– 13 –Non-triggering Example (Trigger Edge = Rising)SONIC Trigger(Trigger Source = 11)0 FallingSampling started when [Sample Value] < [Trigger Thre

Pagina 6

– 14 –Command 4:Conversion Equation Settings{ 4, Equation Number, Equation Type, Number Format, Constants }1. Equation Number0 Clear all Command 4 dat

Pagina 7 - Command 5 - Data Range Setup

– 15 –Command 5: Data Range Settings{ 5, Channel Select, Data Select, Data Begin, Data End, Step, K (, FFT Samples) }Cannot be used during sampling.1.

Pagina 8 - Command 10 - Sensor Warmup

– 16 –Command 7: Status Check{ 7 }After Command 7 is received, this function sends EA-200 status information upon a data request from the calculator.

Pagina 9 - Command 1: Channel Settings

– 17 –Command 10: Power Supply Setting{ 10, Warmup Time (sec) }Supply starts after receipt of Command 10 when supply time is not zero.If a sampling Tr

Pagina 10 - 3. Post-Processing

– 18 –Calculator / PC EA-2000×15 →...← Code A...

Pagina 11 - 6. Trigger Edge

– 19 –䉫 Checksum (1 byte)Checksum is added to the end of every returned header data proper.“Checksum” is the code (hexadecimal number) to check if dat

Pagina 12 - Hysteresis

– 2 –Sampling1. ChannelAnalogPulseDigital I/OMicAnalog OutputCH1–3SONICDIG I/OMicCH3 speaker31111Voltage, resistance, pulse periodChannel NameNumber o

Pagina 13 - 7. Clock Source

–2–SA0601-ACASIO COMPUTER CO., LTD.6-2, Hon-machi 1-chomeShibuya-ku, Tokyo 151-8543, Japan

Pagina 14 - Conversion Equation Settings

– 3 –Analog SamplingChannel Names: CH1, CH2, CH31. CH1, CH2, CH3 Connector SpecificationsPin Number1 Vin ⫾10V (CH3: Vin⫾5V and ⫾3Vout)2 GND3 Vres4 A

Pagina 15

– 4 –3. Data Send Priority1. Real-time Type(Selected using Command 12)Channel Priority: CH1, CH2, CH3, SONIC, DIG IN, sampling time•Variable (1 data)S

Pagina 16 - Command 7: Status Check

– 5 – Channel Operation Post-Processing FFT Samples0 Clear all channels ––– ––– –––*1 Channel 1 0 Clear the selected ch

Pagina 17 - RS-232C Communication

– 6 –Command 3 - Sample and Trigger SetupSampling Interval Number of Samples Record Time0.00002 Number of seconds 1 to Number of samples 0 Offto 16000

Pagina 18 - Packet size 0×FF Area

– 7 –Command 4 - Conversion Equation Setup{ 4, Equation Number, Equation Type, Number Format, Constants }Equation Number Equation Type Number For

Pagina 19

– 8 –Command 6 - System SetupCommand 12 - Data Send Sequence{ 10, Warmup Time (sec) }{ 6, Command, Auto Power Off Time }{ 12, Send Sequence }Command 8

Pagina 20 - 6-2, Hon-machi 1-chome

– 9 –Command 1: Channel Settings{ 1, Channel, Operation, Post-Processing }1. Channel0 Clear all Command 1 data.1 Specify CH1.2 Specify CH2.3 Specify C